746 C - 844 C 47 532150 - Rev.A
F+ -
8.8.
1
2
3
4
5
6
7
8
9
10
11
12
18
19
20
21
22
23
24
CAP
17
16
15
14
13
RADIO
+
RP/DECODER
PE
N
L
DL11
DL10
DL20
DL21
DL24
DL25
DL7
RADIO2
RADIO1
DL17
DL16
DL15
DL14
DL13
DL5
DL6
DL23DL22
DL12
DL1 DL2
Translation of the original instructions
ENGLISH
10. DIAGNOSTICS
SIGNALLING LEDS ON THE BOARD
LED on
LED off
Led flashing
DL1 Bus 2Easy operation
see § Bus 2Easy Devices, § Two-door automation
DL2 (GREEN) Bus 2Easy line diagnostics
RADIO1 XF channel 1 (CH1) in learning mode
idle
memorisation in progress
 2 LEDs flashing al-
ternately: Radio blocked
(error 13)
RADIO2 XF channel 2 (CH2) in learning mode
idle
DL5 Errors/alarms errors/alarms present no errors/alarms -
DL6 Encoder -
stopped
moving (the flashing fre-
quency is related to the
speed)
DL7 EDCL Closing sensitive edges
not engaged
engaged -
DL10 EDOP Opening sensitive edges
not engaged
engaged -
DL11 (BLUE) +24V Accessories power supply +24 V
"
on
off -
DL12 (BLUE) 5V Power supply +5 V
"
on
off -
DL13 IN5 STOP
not active
command active -
DL14 IN4 Closing photocells
not engaged
engaged -
DL15 IN3 Opening photocells
not engaged
engaged -
DL16 IN2 OPEN B (partial opening/closing) command active
idle
-
DL17 IN1 OPEN A (total opening) command active
idle
-
DL20 IN7 CLH (forced closing) command active
idle
-
DL21 IN6 OPH (forced opening) command active
idle
-
DL22 Radio RP channel 1 (CH1) receiving command
idle
-
DL23 Radio RP channel 2 (CH2) receiving command
idle
-
DL24
Opening/closing limit switch (depending
on the direction of travel)
not engaged
engaged -
DL25
not engaged
engaged -