15 COM Motor common contact (BLUE)
16 1 Phase 1 of the electric motor (BLACK)
17 2 Phase 2 of the electric motor (BROWN)
ENCODER
The encoder board is installed and connected at the
factory (connection required for operation).
THRUST CAPACITOR
The capacitor is connected at the factory.
CONNECTING THE EARTH TO THE GEARMOTOR
~ 20 cm
J3
Crimp the system earthing conductor and a similar
cable (3G minimum 1.5 mm), approximately 20 cm
long, onto the cable lug (provided with the hardware/
accessories). Connect to terminal PE of terminal board
J3. Fasten the cable lug to the earth connection of
the gearmotor using the screw and washer provided
with the hardware/accessories.
MAINS POWER SUPPLY
230/115 V~
PE
N
L
Use at least 3G 1.5 mm wire.
PE EARTH (connected previously)
N NEUTRAL
L PHASE
5.4 INSTALLING THE CABLE GLANDS
1. Arrange the individual electrical cables on the rub-
ber strip of elements A and B. Join the elements
and position them on the surface, each with the
slot inserted in the pin.
A
B
3 37
Seat for screw E
Slot
Pin
2. Tighten them together using the screws C and
nuts D and then secure it to the surface using the
screws E.
C
D
D
E
E
C