5. Diagnostics and error handling
5−34
Festo P.BE−CPX−CMA X−SYS−EN en 0908NH
5.3.5 LEDs on the displacement encoder (DGCI only)
LEDs on the DGCI displacement encoder
Power LED Error LED Status CMAX error:
Green Off No error (normal operating status)
Off Off No power supply E80
Off Red Error: Initialising via CAN failed E80
Green Red Error: Magnet not detected or incorrect number of
magnets
E82
Flashes
green
Flashes red Error: Operating voltage not within permissible range E85