5. Diagnostics and error handling
5−37
Festo P.BE−CPX−CMAX−SYS−EN en 0908NH
Possible status information
No. ExampleDescriptionAdditional
Information
Status display
6 3 nn Direct operating mode, position nn in percentage
of the cylinder length
7 4 00 Commissioning operating mode, 00 = ready
8 5 nn Homing active, position nn in percentage of the
cylinder length
9 6 nn Jogging active, position nn in percentage of the
cylinder length
10 7 nn Identification active, current progress nn in %
11 8 nn Movement test active, current progress nn in %
12 t nn Teaching via I/O data active, nn depends on the
current operating mode (display for 1 s)
About 5, 6 The decimal point of the status display flashes as soon as a positioning job is
and 7: active (MC = 0)
About 12: Display of additional information depending on the operating mode for 1 second.
Afterwards, the display switches back to the current/
original status. Record select: 05: Teaching the displayed record number
Commissioning 1: Teach target: Setpoint value
3: Teach target: Project zero point
4: Teach target: Lower software end position
5: Teach target: Upper software end position

Table of Contents

Other manuals for Festo CPX-CMAX-C1-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-CMAX-C1-1 and is the answer not in the manual?

Festo CPX-CMAX-C1-1 Specifications

General IconGeneral
BrandFesto
ModelCPX-CMAX-C1-1
CategoryController
LanguageEnglish

Related product manuals