4. Commissioning
4−9
Festo P.BE−CPX−CMAX−SYS−EN en 0908NH
Delivery status
(first switch−on or after data reset)
The connected components (valve and displacement en
coder/sensor interface) are automatically looked for at
the axis interface. The contained information is read out.
The recognised components are not automatically ac
cepted as the target state.
The controller cannot be activated until the axis data is
completely parameterised
1)
. Actual values are then not
updated.
1)
The target configuration (of the mechanics data) must
have been compared with the actual configuration.
Normal start−up
The connected components (valve and displacement en
coder/sensor interface) are automatically looked for at
the axis interface. The contained information is read out.
The found actual configuration is compared with the
target configuration. If there is a deviation, this leads to
an error and the controller is not activated.
This error can only
be acknowledged after comparing the
target and actual configurations.
Recognisable parameters The CMAX automatically acquires all parameter values
which are stored in the drive, sensor (displacement encoder)
or valve. The FCT plug−in can read these values out of the
CMAX. They do not have to be entered in the FCT project.
The acquired data cannot
be overwritten.

Table of Contents

Other manuals for Festo CPX-CMAX-C1-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CPX-CMAX-C1-1 and is the answer not in the manual?

Festo CPX-CMAX-C1-1 Specifications

General IconGeneral
BrandFesto
ModelCPX-CMAX-C1-1
CategoryController
LanguageEnglish

Related product manuals