34
Maximum data Length as below: -
Customer Code = 18 digit.
Customer Description = 30 digit.
Product Code = 18 digit.
Product Description = 30 digit.
Refer to paragraph 11.4 for creating, recall and clear a customer/product code & description.
11. Quick Access PLU (Quick PLU)
Quick PLUs are available for the below: -
10 Weight check limits for each of the weight units (g, kg, and lb).
10 Quantity check limit for Piece Count Mode for each of the weight units (g, kg, and lb).
10 Preset Tare value for each of the weight units (g, kg, and lb).
10 Average Piece Weight for each of the weight units (g, kg, and lb).
1000 Customer Code & Description.
1000 Product Code & Description.
Notes: -
a. Below paragraphs describe Quick PLU operation through instrument keyboard.
b. Quick PLUs can be created, saved, recalled and cleared by means of computer commands. Refer
to Appendix R and Appendix S for more information.
11.1 Weight Check Limits Quick PLUs
11.1.1 Create & save weight check limits to quick PLU
Follow the below steps to save Lo and Hi weight limits to PLU.
1. Select desired weight unit.
2. Go to Weighing mode and press [Check].
3. Instrument displays Low followed by a 6-digital value. Input the Lo weight limit and press [Print/M+].
4. Instrument displays High followed by a 6-digital value. Input the Hi weight limit. Then press and hold
[Check] for 2 seconds.
5. Instrument displays Save =?. At this point: -
a. Press the preferred PLU position (numeric key 0 ~ 9) and press [Print/M+] to save and utilize
these weight check limits immediately, or
b. Press [Print/M+] to utilize these weight check limits immediately but without saving to PLU, or
c. Press [Zero] to quit.
11.1.2 Recall weight check limits from quick PLU
Follow the below steps to recall weight check limits from quick PLU.
1. Select desired weight unit.
2. Go to Weighing mode. Then press and hold [Check] for 2 seconds.
3. Instrument displays CHK =?. Press PLU position (numeric key 0 ~ 9) and press [Print/M+] to recall the
weight check limits stored in that position.
4. Instrument displays the Lo and Hi weight check limits, and these values are now effective.