35
11.1.3 Clear weight check limits from quick PLU
Refer to paragraph 11.11.1. Input zero value for both Lo and Hi weight check limits in steps number 3 and 4.
11.2 Quantity Check Limits Quick PLUs
11.2.1 Create & save quantity check limits to quick PLU
20
Follow the below steps to save Lo and Hi weight limits to PLU.
1. Select desired weight unit.
2. Go to Piece Count mode and press [Check].
3. Instrument displays Low followed by a 6-digital value. Input the Lo quantity limit and press [Print/M+].
4. Instrument displays High followed by a 6-digital value. Input the Hi quantity limit. Then press and hold
[Check] for 2 seconds.
5. Instrument displays Save =?. At this point: -
a. Press the preferred PLU position (numeric key 0 ~ 9) and press [Print/M+] to save and utilize
these quantity check limits immediately, or
b. Press [Print/M+] to utilize these quantity check limits immediately but without saving to PLU, or
c. Press [Zero] to quit.
11.2.2 Recall quantity check limits from quick PLU
Follow the below steps to recall weight check limits from quick PLU.
1. Select desired weight unit.
2. Go to Piece Count mode. Then press and hold [Check] for 2 seconds.
3. Instrument displays CHK =?. Press PLU position (numeric key 0 ~ 9) and press [Print/M+] to recall the
quantity check limits stored in that position.
4. Instrument displays the Lo and Hi quantity check limits, and these values are now effective.
11.2.3 Clear quantity check limits from quick PLU
Refer to paragraph 11.2.1. Input zero value for both Lo and Hi quantity check limits in step 3 and 4.
11.3 Preset Tare Value Quick PLUs
21
11.3.1 Create & save preset tare value to quick PLU
22
Follow the below steps to save Lo and Hi weight limits to PLU.
1. Select desired weight unit.
2. Go to the desired operation mode. Input preset tare value, then press and hold [Tare] for 2 seconds.
3. Instrument displays Save =?. At this point: -
a. Press the preferred PLU position (numeric key 0 ~ 9) and press [Print/M+] to save to that PLU
position, or
b. Press [Print/M+] to utilize this preset tare value immediately but without saving to PLU, or
c. Press [Zero] to quit.
20
10 quick PLUs are available for each weight unit kg, g, and lb.
21
Preset tare value PLU does not support ATM mode.
22
10 quick PLUs are available for each weight unit kg, g, and lb.