38
12.1 Obtaining Average piece weight
12.1.1 By manual entry method
1. Press [Unit] twice to go to average piece weight entry page.
2. Input the average piece weight and press [Print/M+].
3. Average piece weight is now in effect.
12.2 By Sampling Method
1. Apply samples with known quantity (sample quantity).
2. Press [Set], then input the sample quantity and press [Print/M+].
3. This instrument will calculate, store the average piece weight and confirm with 2 beeps. The quantity is
then displayed.
4. Add to or remove, the corresponding quantity will be updated.
5. To count different articles, repeat the above steps.
12.3 Auto Average piece weight Enhancement Function
To obtain the best piece count result and minimize sampling error, this instrument is equipped with Auto Average
piece weight Enhancement Function.
Refer to F11 of paragraph 6.4 on how to enable/disable this function.
This function starts when all of the below conditions are met: -
1. It is set to On in F11.
2. Average piece weight is determined by the actual sampling method as listed on 12.2.
3. The quantity added is more than 5 pieces but less than the current quantity.
4. The total quantity is less than 10,000 pieces.
When all the above requirements are met, a new average piece weight will be calculated and stored in memory
and confirmed by a "beep" sound.
12.4 Shift among Quantity, Average piece weight & Weight Info
Press [Unit] to shift among quantity, average piece weight, and weight info.
• Quantity display format = numeric numbers & pieces (e.g1000 pieces).
• Average piece weight display format = numeric numbers & weight unit &/piece (e.g. 499.960g/piece).
• Weight display format (when Piece Count Function is in effect) = numeric numbers & weight unit &
piece (e.g. 500g piece).
12.5 Recall the Average piece weight before Powered Off
1. Press [Unit] until instrument displays quantity screen.
2. Press [Set] then [MR] to recall the average piece weight before power off.