45
19. Alibi Transaction Memory & Management Report
19.1 Alibi Memory Description
This instrument is equipped with Alibi memory to record all individual transaction records. Management reports
can be generated based on data saved in transaction memory, and: -
• The criteria set in F71 (supervisor password is needed to access this internal function), and
• The format set in F33, and
• The search criteria and time duration set in F34.
Notes: -
• The Alibi memory is independent to those data obtained through memory accumulation (e.g., manual
memory accumulation by pressing [Print/M+] key and auto accumulation result by ACC = On in
transmission type Manual and Auto 1 ~ Auto 3) during an operation.
• Maximum records can be saved = 131,072 transactions.
• When remaining memory is low: - Instrument displays Li xxx in power on countdown process. xxx is the
number of memory remains before instrument starts overwriting historical records.
• When memory is full: - Instrument overwrites old records with new records based on first in first out
principle.
An Alibi Management report is constructed of the followings: -
a. Report Title, which shows the report output data range and search criteria.
b. Report Header explains the nature of an output column.
c. Content of Individual transactions.
d. Footer, which shows 4 different kinds of totalized results. Refer to paragraph 19.5 for more
information.
To enable/disable Title, Header, and Footer output, simply select On or Off when asked. Refer to step 6 of
F33 in paragraph 6.4 for settings.