Protocol 0 Output Format
Position
1
2
3
4
5
6
7
8
9
10
Data
+,-
A
A
A
A
A
A
A
CR
LF
Protocol 1 Output Format
Position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Data
S
S
,
G/N
+,-
W
W
W
W
W
W
W
,
U
U
CR
LF
Protocol 2 Output Format
Position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Data
STX
SWA
SWB
SP
Field 1 (Net Weight)
Field 2 (Tare Weight)
CR
Protocol 3 Output Format
Position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Data
SOH
STX
SP
+,-
W
W
W
W
W
W
W
SP
U
U
SP
SP
SP
SP
CR
LF
Protocol 4 Output Format
Position
1
2
3
4
5
6
7
8
9
Data
=
R
R
R
R
R
R
R
P
Protocol 5 Output Format
Position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Table of Contents