FLEX-6000 Signature Series – Maestro User Guide
Copyright 2024 FlexRadio, Inc. All Rights Reserved. | Page 132
The CAT commands supported on CAT cables are:
FA and ZZFA: Report the source frequency, Get/Read Only
FB and ZZFB: Report the source frequency, Get/Read Only. FA and FB report the same
information.
FR: Reports which slice is the receiver (0 or 1) which corresponds to the slice that is NOT the
transmitter.
FT: Report or set the transmit slice.
SP: Report the status of split mode or enter split mode.
SB: Report the status of a “sub-band receiver”. This command will report “SB0” when a
single SCU is in use, or “SB1” when more than one SCU is in use.
IF and ZZIF: Report the source frequency as well as mode and other parameters, Get/Read
Only
AI and ZZAI: Set 'auto-report' enabled/disabled
o If Auto-report is FALSE, then the external device must poll by sending a command
through the USB Cable. If Auto-report is TRUE, then anytime the source frequency
changes it is automatically sent on the CAT cable
PC: Used to set and get the current power level