Nominal frequency for Full Backup
53 / 63 Hz
1)
Total harmonic distortion < 3.5%
Power factor cos phi
2)
0-1 (adjustable)
0.7-1 (recommended)
Max. permitted mains impedance Z
max
at PCC
4)
None
Maximum output fault current / dura-
tion
80.7 A / 10 ms
AC output data PV Point
Max. output power 4133 W (for 5 s)
Rated power 3000 W
Nominal output current 13 A
Nominal mains voltage 1 ~ NPE 220 V / 230 V / 240 V
Nominal frequency
53 / 63 Hz
1)
Switchover time < 90 s
Power factor cos phi
2)
0 - 1
AC output data Full Backup
8)
Max. output power 12400 W (for 5 s)
Max. output power (per phase) 4133 W (for 5 s)
Rated power 8000 W
Rated power (per phase)
7)
3680 W
Nominal output current (per phase) 16 A
Nominal mains voltage 3 ~ NPE 220 V / 380 V
3 ~ NPE 230 V / 400 V
Nominal frequency for Full Backup
53 / 63 Hz
1)
Switchover time < 90 s
Power factor cos phi
2)
0 - 1
General data
Maximum efficiency 98.2%
European efficiency (U
mpp nom
) 97.8%
European efficiency (U
mpp max
) 97.5%
European efficiency (U
mpp min
) 96.9%
Self-consumption at night ≤ 10 W
Cooling Controlled forced-air ventilation
Protection class IP 66
Dimensions H x W x D 595 × 529 × 180 mm
Weight 24 kg
Inverter topology Non-insulated transformerless
Permitted ambient temperature -25 °C - +60 °C