With parts sourced from other suppliers, there is no certainty that these parts
will have been designed and manufactured to cope with the stressing and
safety requirements that will be made of them. Use only original spares and
wearing parts (this also applies to standard parts).
Do not make any alterations, installations or modifications to the machine
without getting permission from the manufacturer first.
Replace immediately any components that are not in perfect condition.
When ordering spare parts, please state the exact designation and the
relevant part number, as given in the spare parts list. Please also quote the
serial number of your machine.
Preventive and
corrective main-
tenance
- If any damage occurs in cases where other coolants have been used, the
manufacturer shall not be liable for any such damage, and all warranty
claims shall be null and void.
- Under certain conditions, the coolant is flammable. Only transport the
coolant in closed original containers, and keep it away from sources of
ignition.
- Used coolant must be disposed of properly in accordance with the
relevant national and international regulations. A safety data sheet is
available from your service centre and on the manufacturer’s homepage.
- Before starting welding - while the machine is still cool - check the
coolant level.
Safety precauti-
ons in normal
operation
(continued)
The owner/operator is obliged to have a safety inspection performed on the
machine at least once every 12 months.
The manufacturer also recommend the same (12-month) interval for regular
calibration of power sources.
A safety inspection, by a trained and certified electrician, is prescribed:
- after any alterations
- after any modifications or installations of additional components
- following repairs, care and maintenance
- at least every twelve months.
Observe the relevant national and international standards and directives in
connection with the safety inspection.
More detailed information on safety inspections and calibration is available
from your regional or national service centre, who will be pleased to provide
you with copies of the necessary documents upon request.
Safety inspection
Do not dispose of this device with normal domestic waste!
To comply with the European Directive 2002/96/EC on Waste Electrical and
Electronic Equipment and its implementation as national law, electrical
equipment that has reached the end of its life must be collected separately
and returned to an approved recycling facility Any device that you no longer
require must be returned to our agent, or find out about the approved collec-
tion and recycling facilities in your area.
Ignoring this European Directive may have potentially adverse affects on the
environment and your health!
Disposal

Table of Contents

Other manuals for Fronius VR 5000

Related product manuals