45
If the rod electrode (MMA) welding process is selected, any cooling unit present is
automatically deactivated. It is not possible to switch it on.
Important! Parameters that have been set on a system component control panel
(e.g. remote control unit) may not be able to be changed on the wire-feed unit
control panel.
3. Use the wirespeed adjuster to set the desired amperage.
The parameter values are shown in the digital indicator located above them.
4. Start welding
MMA welding -
manual control
panel
(continued)
Adjustments
while welding -
manual control
panel
To obtain the best possible welding results, the dynamic correction parameter will some-
times need to be adjusted.
1. Set the required arc-force dynamic using the Dynamic buttons.
The value of the parameter is indicated by the LEDs located between the buttons.
Arc-force dynamic
for influencing the short-circuiting dynamic at the instant of droplet transfer
- harder, more stable arc
+ soft, low-spatter arc
MMA welding -
Synergic A
control panel
1. Move the mains switch to the „I“ position: All the indicators on the control panel light
up briefly
2. Press the Process button to select the MMA welding process:
CAUTION! Risk of injury and damage from electric shock. As soon as the
mains switch is in the „I“ position, the rod electrode in the electrode holder is
LIVE. Make sure that the rod electrode does not touch any persons or electri-
cally conducting or earthed parts (e.g. the housing etc.)
The welding voltage is connected to the welding socket with a 3-second time lag.
If the rod electrode (MMA) welding process is selected, any cooling unit present is
automatically deactivated. It is not possible to switch it on.
Important! Parameters that have been set on a system component control panel
(e.g. remote control unit) may not be able to be changed on the wire-feed unit
control panel.