30
NOTE! Adjust the contact pressure in such a way that the wire electrode is not
deformed, but is nevertheless transported properly.
Setting the
contact pressure
Contact pressure guideline values U-grooved rollers
Steel 4 - 5
CrNi 4 - 5
Tubular cored electrodes 2 - 3
1
1
3
2
4
5
3
1
4
1
1
2
3
Feeding in the
wire electrode
(continued)