EasyManua.ls Logo

Fujitsu ETERNUS DX100 S3 - Page 1075

Fujitsu ETERNUS DX100 S3
1082 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix H Storage Migration Setting Files
H.1 Template File for Storage Migration Settings
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
1075
GROUP PATH Specify the path information of the destination
and source storage systems.
Up to 8 paths per path group can be specified.
[Example]
For the ETERNUS DX8700 S3/DX8900 S3
PATH=CEx,CMy,CAz,Pw,vvvvvvvvvvvvvvvv
For the other models
PATH=CMy,CAz,Pw,vvvvvvvvvvvvvvvv
x: CE number, y: CM number, z: CA number,
w: Port number
vvvvvvvvvvvvvvvv: WWN
4–
CE Specify the location information (CEx,
CMy, CAz, Pw) of the destination FC-
Initiator port to which the path is
configured.
For the ETERNUS
DX8700 S3/DX8900 S3
CEx, CMy, CAz, Pw
For the other models
CMy, CAz, Pw
x: CE number
y: CM number
z: CA number
w: Port number
CM
CA
P
WWN Specify the World Wide Name (WWN) of
the source FC-Initiator port to which the
path is configured.
16-digit hexadecimal
GROUP VOL Specify the source LUN (Y) and the destination
volume (Z).
The maximum number of source LUNs for each
migration path (PATH) is 512.
[Example] VOL=Y, Z
Example of specifying source LUNs and
destination volumes
Source LUN:
0 - 255
(decimal)
0xYYYY
(4-digit hexadecimal)
0xYYYYYYYYYYYYYYYY
(16-digit hexadecimal)
Destination volume:
Z (decimal)
0xZZZZ
(4-digit hexadecimal)
Keyword Number of
settings
Allowed input
Source LUN Destination volume
Input a decimal number
Specification method: "0x"
is not added on top of the
value.
Decimal numbers can be
used only when the source
LUN is from "0" to "255".
Input a decimal number
Specification method:
"0x" is not added on top of
the value.
Input a hexadecimal number
(4-digit)
Specification method:
Add "0x" on top of the value.
Input in "0xYYYY" format.
Input a hexadecimal number
(4-digit)
Specification method:
Add "0x" on top of the value.
Input in "0xZZZZ" format.
Input a hexadecimal number
(16-digit)
Specification method:
Add "0x" on top of the value.
Input in
"0xYYYYYYYYYYYYYYYY"
format.

Table of Contents

Other manuals for Fujitsu ETERNUS DX100 S3

Related product manuals