Chapter 6 Thin Provisioning Pool Management
6.10 Assign Eco-mode Schedule (Thin Provisioning Pool)
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
584
6.10 Assign Eco-mode Schedule (Thin Provisioning Pool)
This function assigns the Eco-mode schedule to the Thin Provisioning Pools (TPPs) and sets the Eco-mode
action.
Eco-mode is a function to reduce power consumption by stopping the drive motors or turning off the drives
that configure the TPP while the TPP is not accessed from the host. There are three Eco-mode actions; "Drive
motor off", "Drive power off", and "Drive always on".
To enable the Eco-mode, assign the Eco-mode schedule to TPP and select "Drive motor off" or "Drive power off"
as the Eco-mode action. When Eco-mode is enabled, the drives are activated during the scheduled event
period. In the time periods outside the scheduled event, the drive status is changed according to the specified
Eco-mode actions. Refer to "Drive status when Eco-mode action is configured (for TPP)" (page 584)
for details.
If the TPP is accessed from the host while the drives are turned off or the drive motors are stopped, the drives
are activated and can be accessed within 1 - 5 minutes.
Drive status when Eco-mode action is configured (for TPP)
*1: If the TPP is accessed, the drives are activated and can be accessed within 1 - 5 minutes.
Eco-mode Schedule Setting
Eco-mode General Setting
Enabled Disabled
Drive power Drive motor
Eco-mode Action
Drive power
off
During
scheduled event
term
Drive power is on
Drive motor is
activated
Drive power is on
or the drive motor
runs regardless of
the schedule.
Times other than
scheduled event
term (*1)
Drive power is off
Drive motor is
stopped
Drive motor
off
During
scheduled event
term
Drive power is on
Drive motor is
activated
Times other than
scheduled event
term (*1)
Drive power is on
Drive motor is
stopped
Drive always on Drive power is on
Drive motor is
always activated
Eco-mode schedule is not assigned Drive power is on
Drive motor is
always activated
Drives not registered in the TPPs Drive power is on
Drive motors are
always stopped