Chapter 1 System Management
1.12 Storage Migration Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
183
The procedure to start Storage Migration is as follows:
Procedure
1 Click [Start] in [Action].
2 Click the [Browse...] button to select a Storage Migration setting file.
The main setting item is as follows.
Storage Migration
Storage migration setting file
An error screen is displayed when a timeout occurs during the retrieval of destination device
information.
An error screen is displayed when the Storage Migration setting file is in the following conditions:
- The Storage Migration setting file is not specified
- A character code other than the space or tab is placed before the keyword on the left of "="
- The number of the parameters on the right of "=" does not coincided with the specified number
of parameters of the keyword
- The identification code is invalid
- "Type" is not "Open"
- The "GROUP" is in the following conditions
Invalid characters are input
- A value other than a 1-digit hexadecimal number is input after the "0x" prefix
Out of range (not in the 0 - F range)
The same value is duplicated in the Storage Migration setting file
- The Operation mode is not one of the following items: "M", "M+QC", "M+FC", "QC", "FC"