Chapter 7 Advanced Copy Management
7.7 Modify Copy Parameters
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
609
For details on the parameters for this function, refer to "A.7.4 Modify Copy Parameters" (page 941).
For the factory default settings for this function, refer to "Appendix B Modify Copy Parameters" (page 1010)
.
The procedure to modify copy parameters is as follows:
1 Click [Modify Copy Parameters] in [Action].
2 Specify the threshold for each policy level.
The main setting items are as follows.
● Policy of Snap Data Pool
• Policy Level 1 (Informational) Threshold
• Policy Level 2 (Warning) Threshold
• Policy Level 3 (Error) Threshold
● SDPE Setting
• SDPE
3 Click the [Modify] button.
A confirmation screen appears.
4 Click the [OK] button.
The specified copy parameters are registered.
5 Click the [Done] button to return to the [Snap Data Pool] screen.
If the magnitude relation is not "Threshold for a policy level 1" < "Threshold for policy level 2" <
"Threshold for policy level 3", an error screen appears. If this occurs, check the parameter settings.