Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
679
PWC Connection Settings
Connection CM
Connection SVC
Delay until Shutdown
Description Select the checkbox for the controller module (CM) to enable power management by an
external input device (multiple selections can be made).
When this item is selected, set "Delay until Shutdown", "Set management unit interface",
"Power Failure Signal", "Low Battery Signal" and "UPS Shutdown Signal".
This item is displayed for the ETERNUS DX60 S3/DX100 S3/DX200 S3, the ETERNUS DX500
S3/DX600 S3, and the ETERNUS DX200F.
Input condition/
Display contents
Checkbox for CM
Selected
Cleared
Description Select the checkbox for the Service Controller (SVC) to enable power management by an
external input device (multiple selections can be made).
When this item is selected, set "Delay until Shutdown", "Set management unit interface",
"Power Failure Signal", "Low Battery Signal" and "UPS Shutdown Signal".
This item is displayed only for the ETERNUS DX8700 S3/DX8900 S3.
Input condition/
Display contents
Checkbox for SVC
Selected
Cleared
Description Specify the delay time (minutes) before starting shutdown after receiving a shut down
notification signal from the external input device.
When PMAN is connected, specify the delay time before starting shutdown after
receiving a low battery signal. Specify a delay time longer than the time required for the
server shutdown process so that the ETERNUS DX is turned off after the server shutdown
is complete.
Input condition/
Display contents
0 - 15