Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED P2X0-1270-13ENZ0
741
• Virus Scan Server Connection Recovered
• Virus Pattern File Update
• Virus Scan Engine Update
Initial state list
The initial state of event notification is as follows:
Selected: Notify
Cleared: Not notify
Selected/Cleared: Some events are notified and other events are not notified
–: Not applicable to notification
Description Select whether to notify when a communication error with the virus scan server is recov-
ered in the NAS system. When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
Description Select whether to notify when the latest virus scan pattern file is applied in the NAS sys-
tem. When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
Description Select whether to notify when the latest virus scan engine is applied in the NAS system.
When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
Item Notification method
Host Sense Key
Code Qualifier
SNMP Trap E-Mail syslog REMCS AIS
Connect
All Error Events Selected/
Cleared
Selected/
Cleared
Selected/
Cleared
Cleared Selected/
Cleared
Selected/
Cleared
All Warning Events Selected Selected Selected Cleared Cleared Selected
All Informational Events – Selected/
Cleared
Selected/
Cleared
Cleared Cleared Selected/
Cleared
Individual Settings
within Severity Level
Yes Yes Yes No Yes Yes
Event Notification Remarks
Blink Fault LED at warning Enable
–
Turn on Fault LED when redundant copy is completed Disable –
Display parts (except drive) with error status on LCD Enable They are displayed only for the
ETERNUS DX8700 S3/DX8900 S3.
Display parts (except drive) with warning status on LCD Enable
Display drives with error status on LCD Any Time Enable
when HS<0 Disable
Display drives with warning status on LCD Any Time Enable
when HS<0 Disable