EasyManua.ls Logo

Fujitsu XG0224 - Page 569

Fujitsu XG0224
631 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XG Series User's Guide Chapter 6 Managing the Device
Verifying the Device Operations
569
slot2_temp
temperature around Expansion Card (SLOT2).
At the time of three following states, "--" is displayed.
The Expantion Card without Thermal Sensor is installed. (CX4)
The Invalid Expantion Card is installed.
The Expantion Card is not installed.
9) Slot Information
The type of Expansion Card.
SJ10GCX4Z : Installed Expansion Card is SJ10GCX4A. (CX4)
SJ10GSFPZ : Installed Expansion Card is SJ10GSFPA. (SFP+)
NO_PRESENT : The Expantion Card is not installed.
UNKNOWN : Installed Expansion Card is Invalid Card.
10) power_consumption
Power consumption of the device.
XG0440DC / XG0440DCR
1) Current time
Present date and time.
2) Startup time
Date and time when the system started up.
3) restart_cause
Cause for the system startup.
The following system startup causes are displayed:
power on : The power has been turned on.
reset : The reset command has been issued.
reset switch : The [RESET] switch has been pressed.
system down : System-down has occurred.
4) machine_state
State of the device
RUNNING : The device is active.
FALLBACK : The device is into fallback state.
5) access_direction
Direction where a device is installed in.
front access : The device should be installed forward. (XG0440DC)
rear access : The device should be installed backward. (XG0440DCR)
# show system status
Current-time :
Fri Dec 18 17:04:50 2009 ---(1)
Startup-time :
Fri Dec 18 16:04:36 2009 ---(2)
restart_cause : power on ---(3)
machine_state : RUNNING ---(4)
access_direction :
rear access ---(5)
power_redundancy : redundant ---(6)
PSU1 state : NORMAL ---(7)
PSU2 state : NORMAL
PSU1 type : AC ---(8)
PSU2 type : AC
power_consumption : 78 W ---(9)
FAN state : NORMAL ---(10)
inspiration_state : NORMAL ---(11)
warning time :
Fri Dec 18 17:00:45 2009 ---(12)
recover time :
Fri Dec 18 17:02:30 2009
internal_state : NORMAL
inspiration_temp : 28 C ---(13)
internal_temp : 33 C

Table of Contents