XG Series User's Guide Chapter 6 Managing the Device
Verifying the Device Operations
570
6) power_redundancy
State of the redundant power unit.
single : The device has no redundant power unit.
redundant : The device has a redundant power unit.
7) PSU1 state
State of the power unit (PSU1).
PSU2 state
Type of the power unit (PSU2).
NORMAL : The power unit works normally.
NO PRESENT : The power unit is not installed.
NO POWER : The power unit has been turned off.
FAIL : The power unit has been abnormal.
UNKNOWN : The power unit is invalid type.
WARNING : The power unit has been incorrectly mounted.
8) PSU1 type
Type of the power unit (PSU1).
PSU2 type
Type of the power unit (PSU2).
AC : The power unit is AC.
-- : The power unit is not installed or invalid type.
9) power_consumption
Power consumption of the device.
10) FAN state
State of the fan module 1.
NORMAL : The fan module works normally.
FAIL : The fan module has been abnormal.
NO PRESENT : The fan module is not installed.
UNKNOWN : The fan module is invalid direction.
WARNING : The fan module has been incorrectly mounted.
11) inspiration_state
State of environment temperature monitor.
internal_state
State of device inside temperature monitor.
NORMAL : The temperature is normal.
WARNING : The device changes to a high temperature state.
ALARM : Thermal alarm occurs in the device.
12) State of changing thermal state
warning time : The time when a device changed in a high temperature state.
recover time : The time when a device returned to a normal state.
13) inspiration_temp
Environment temperature.
internal_temp
Device inside temperature.