XG Series User's Guide Chapter 6 Managing the Device
Verifying the Device Operations
571
XG2600
1) Current time
Present date and time.
2) Startup time
Date and time when the system started up.
3) restart_cause
Cause for the system startup.
The following system startup causes are displayed:
power on : The power has been turned on.
reset : The reset command has been issued.
reset switch : The [RESET] switch has been pressed.
system down : System-down has occurred.
4) machine_state
State of the device
RUNNING : The device is active.
FALLBACK : The device is into fallback state.
5) access_direction
Direction where a device is installed in.
front access : The device should be installed forward.
rear access : The device should be installed backward.
6) power_redundancy
State of the redundant power unit.
single : The device has no redundant power unit.
redundant : The device has a redundant power unit.
7) PSU1 state
State of the power unit (PSU1).
PSU2 state
Type of the power unit (PSU2).
NORMAL : The power unit works normally.
NO_PRESENT : The power unit is not installed.
NO_POWER : The power unit has been turned off.
FAIL : The power unit has been abnormal.
UNKNOWN : The power unit is invalid type.
WARNING : The power unit has been incorrectly mounted.
# show system status
Current-time : Thu Dec 21 16:04:50 2008 ---(1)
Startup-time : Thu Dec 21 16:04:36 2008 ---(2)
restart_cause : power on ---(3)
machine_state : RUNNING ---(4)
access_direction : front access ---(5)
power_redundancy : redundant ---(6)
PSU1 state : NORMAL ---(7)
PSU2 state : NORMAL
PSU1 type : AC ---(8)
PSU2 type : AC
power_consumption : 75 W ---(9)
FAN1 state : NORMAL ---(10)
FAN2 state : NORMAL
inspiration_state : NORMAL
inspiration_temp : NORMA ---(11)
warning time : Fri Dec 26 14:00:45 2008 ---(12)
recover time : Fri Dec 26 14:12:30 2008
internal_state : NORMAL
inspiration_temp : 35 C ---(13)
internal_temp : 32 C