XG Series User's Guide Chapter 6 Managing the Device
Verifying the Device Operations
572
8) PSU1 type
Type of the power unit (PSU1).
PSU2 type
Type of the power unit (PSU2).
AC : The power unit is AC.
-- : The power unit is not installed or invalid type.
9) power_consumption
Power consumption of the device.
10) FAN1 state
State of the fan module 1.
FAN2 state
State of the fan module 2.
NORMAL : The fan module works normally.
FAIL : The fan module has been abnormal.
NO_PRESENT : The fan module is not installed.
UNKNOWN : The fan module is invalid direction.
WARNING : The fan module has been incorrectly mounted.
11) inspiration_state
State of environment temperature monitor.
internal_state
State of device inside temperature monitor.
NORMAL : The temperature is normal.
WARNING : The device changes to a high temperature state.
ALARM : Thermal alarm occurs in the device.
12) State of changing thermal state
warning time : The time when a device changed in a high temperature state.
recover time : The time when a device returned to a normal state.
13) inspiration_temp
Environment temperature.
internal_temp
Device inside temperature.
The following example shows the information that is displayed when the "show ether media-info" command is entered.
Execution Example
Execution Example (XG0224)
# show ether media-info
Port media type Vendor PN
---- ---------- ----------------
(1) (2) (3)
21 SFP(SX) HFBR-5710L
22 SFP(ZX) SCP6P94-F7-BMH
23 SFP(LX) SCP6P44-F7-BMH
24 SFP(FX) HFBR-57E0P
25 SFP+(LR) FTLX1471D3BCL
26 SFP+(SR) TRS2000EN-S002