AP2-11
42. Warning 9213: (HUB) RAM fault.
The status for this error is confirmed during selftest. This will be issued when there is
an error for reading from/writing into the RAM in HUB board. Please replace the
board. It implies a failure in the HUB board.
43. Error 9214: (HUB) Audio Codes initialization fault.
The status for this error is confirmed when the system is activated. This error occurs
when initialization has failed for the Audio Codes IC for the HUB board. Please
reboot the system. If the same failure occurs even after having rebooted the system,
replace the board. It implies a failure in the HUB board.
44. Error 9301: (Modem) FPGA fault.
The status for this error is confirmed when the system is activated. This message will
be output when FPGA configuration has failed for the MODEM board. Please update
the MODEM software. It implies a failure in the MODEM board.
45. Warning 9302: (Modem) Getting GPS fault.
The status for this error is constantly confirmed at an interval of 2 seconds. This error
occurs when GPS data cannot be obtained. Please wait until GPS data can be received.
If the GPS data cannot be received, please check the GPS status in Web MMI. It
implies a failure in the GPS antenna, GPS core, or the MODEM board. When the
GPS data cannot be obtained, communication will not be available. Please have
External GPS input.
46. Error 9303: (Modem) Loading DSP1 fault.
The status for this error is confirmed when the system is activated. This error occurs
when activation of DSP1 for the MODEM board has failed. Please update the
MODEM software. It implies a failure in the MODEM board.
47. Error 9304: (Modem)DSP1 fault.
The status for this error is constantly confirmed at an interval of 3 seconds. This error
occurs when abnormality is detected in DSP1 for the MODEM board. Please reboot
the system. Please update the MODEM software. It implies a failure in the MODEM
board.
48. Error 9305: (Modem) Loading DSP2 fault.
The status for this error is confirmed when the system is activated. This error occurs
when activation of DSP2 for the MODEM board has failed. Please update the
MODEM software. It implies a failure in the MODEM board.

Table of Contents

Other manuals for Furuno FELCOM 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 250 and is the answer not in the manual?

Furuno FELCOM 250 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 250
CategoryMarine GPS System
LanguageEnglish

Related product manuals