Appendix 2. Message List
AP2-12
49. Error 9306: (Modem) DSP2 fault.
The status for this error is constantly confirmed at an interval of 3 seconds. This error
occurs when abnormality is detected in DSP2 for the MODEM board. Please reboot
the system. Please update the MODEM software. It implies a failure in the MODEM
board.
50. Error 9307: (Modem) Loading DSP3 fault.
The status for this error is confirmed when the system is activated. This error occurs
when activation of DSP3 for the MODEM board has failed. Please update the
MODEM software. It implies a failure in the MODEM board.
51. Error 9308: (Modem) DSP3 fault.
The status for this error is constantly confirmed at an interval of 3 seconds. This error
occurs when abnormality is detected in DSP3 for the MODEM board. Please reboot
the system. Please update the MODEM software. It implies a failure in the MODEM
board.
52. Error 9309: (Modem) HPI fault.
The status for this error is confirmed on a constant basis when sending/receiving HPI.
This message is displayed when there is an abnormality such as the buffer being
FULL for the communication between the DSP for the MODEM board and the CPU
(SH4). Please update the MODEM software. It implies a failure in the MODEM
board.
53. Warning 9310: (Modem) Temperature low.
The status for this error is constantly confirmed at an interval of 3 seconds. This error
occurs when the temperature of MODEM board gets below -25 degrees. It implies a
failure in the MODEM board.
54. Warning 9311: (Modem) Temperature high.
The status for this error is constantly confirmed at an interval of 3 seconds. This error
occurs when the temperature of MODEM board gets below -80 degrees. It implies a
failure in the MODEM board.
55. Warning 9312: (Modem) 5 V power supply fault.
The status for this error is constantly confirmed at an interval of 3 seconds. This error
occurs when there is an abnormality in the 5 V voltage (where the voltage gets below
4.0 V or more than 6.0 V) for the MODEM board. It implies a failure in the MODEM
board.
56. Warning 9313: (Modem) 6 V power supply fault.
The status for this error is constantly confirmed at an interval of 3 seconds. This error
occurs when there is an abnormality in the 6 V voltage (where the voltage gets below
5.0 V or more than 7.0 V) for the MODEM board. It implies a failure in the MODEM
board.

Table of Contents

Other manuals for Furuno FELCOM 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FELCOM 250 and is the answer not in the manual?

Furuno FELCOM 250 Specifications

General IconGeneral
BrandFuruno
ModelFELCOM 250
CategoryMarine GPS System
LanguageEnglish

Related product manuals