AP2.7 Power supply
AP2-18
AP2.7 SPECIFICATIONS OF THE AC/DC CHANGE-OVER UNIT
AP2.7.1 Battery charger & Rectifier
1. BATTERY CHARGER (BC-6158)
(1) Applicable Battery 200 AH Normal ship battery
(2) Power Source 100/110/200/220 VAC, 1 phase, 50/60 Hz
(3) Output for Battery 28 VDC, 30 A nominal
(4) Charge/discharge Meter built in the radio console panel
(5) Control Panel built in the radio console
2. RECTIFIER (PR-850AR)
(1) Power Source 100/110/120/200/220/240 VAC, 1 phase, 50/60 Hz or 24 VDC
(2) Input Current 15 A or less (100VAC input, 30 A output),
30 A or less (100 VAC input, 60A output)
(3) Output Voltage 24 V DC ±10%, 30 A
(4) Peak Output Current 60 A (within 1 min at AC supply)
40A (within 1 min at DC supply)
(5) Ripple Voltage 200 mVp-p or less
(6) Insulation Resistance 500 VDC, 10 M
or more between AC input and chassis
3. RECTIFIER (PR-300)
(1) Power Source 100/110/200/220 VAC, 1 phase, 50/60 Hz or 24 VDC
(2) Input Current 4.1 A or less (100VAC input), 3.1 A or less (DC input)
(3) Output Voltage 24 VDC ±10%, 7.5 A
(4) Peak Output Current 20 A (with rated output current: 15 A, 250 msec, duty 50 %)
(5) Ripple Voltage 100 mVp-p or less
(6) Insulation Resistance 500 VDC, 50 M
or more between AC input and chassis