CS875-575-375-275-175 Installers Manual with CS5500 keypadB.13.7
13.4 Glossary
Location Term Definition
13 CS7002 GPRS Module A module that operates as a GPRS and GSM communications module for
reporting and upload/download.
13.1 Reporting A menu entry that groups reporting options.
13.1.1 Report Control A block of reporting data that contains configurations to format selected events
into one or more messages according to pre-configured settings and send
them to specified destinations.
A menu entry that groups report control options.
13.1.1.1.1 Destination A menu option that configures the report destination for the selected report
control.
13.1.1.1.2 Backup Destination A menu option that configures the backup destination for the selected report
control. If using another device as the backup destination, set the reporting
format in Reporting>Backup Format and enable test report events in the
backup device.
13.1.1.1.3 Events A menu entry that contains all configurable events for each report control. All
events for report control 1 are enabled by default. Events for all other report
controls are disabled by default. Enabled events are formatted into one or
more messages according to pre-configured settings and sent to the selected
report destination. You must enable only Test Reports if using the CS7002 as
backup to another auxiliary dialler.
13.1.1.1.3.1 Arm/Disarm/Alarm A menu entry that groups the events that are reported to the selected report
control.
13.1.1.1.3.1.1 Alarms A menu option that sends a report to the selected report control when an alarm
occurs.
13.1.1.1.3.1.2 Alarm Restores A menu option that sends a report to the selected report control when the
alarm has been restored after an alarm.
13.1.1.1.3.1.3 Opening/Closings A menu option that sends a report to the selected report control stating when
the system is opened (disarmed) and closed (armed).
13.1.1.1.3.1.4 Zone Bypass and Restores A menu option that sends a report to the selected report control when a zone is
bypassed. A report is also sent when the zone is restored (un-bypassed).
13.1.1.1.3.2 Tamper/Trouble A menu entry that groups together the tamper and trouble events that are
reported to the selected report control.
13.1.1.1.3.2.1 Tampers and Restores A menu option that sends a report to the selected report control when a tamper
occurs. A report is also sent when the tamper is no longer active.
13.1.1.1.3.2.2 Zone Trouble and Restores A menu option that sends a report to the selected report control when a zone
trouble condition occurs. A report is also sent when the trouble condition is no
longer active.
13.1.1.1.3.2.3 Expander Trouble and Restores A menu option that sends an expander trouble and restore report to the
selected report control.
13.1.1.1.3.2.4 Siren/Phone Faults and Restores A menu option that sends a report to the selected report control when a siren
or phone fault occurs. A restore report is sent when the fault is fixed.
13.1.1.1.3.2.5 RF Sensor Lost and Restores A menu option that sends a report to the selected report control when an RF
sensor is missing. A restore report is sent to the central station when the
receiver receives a valid signal from the lost transmitter.
13.1.1.1.3.2.6 RF Low Battery and Restores A menu option that sends a report to the selected report control when a low
battery condition occurs in an RF sensor. A restore report is also sent when the
low battery condition is no longer active.