CS875-575-375-275-175 Installers Manual with CS5500 keypad B.2.6
3. Scroll to Keyswitch Arming>Yes and press OK.
4. The keypad beeps once to confirm the change and returns to Keyswitch Arming.
2.3.3 Programming the keypad sounder
You can specify conditions and/or events that activate the keypad sounder. To configure the sounder, you must
enable the advanced menu. The following example programs the keypad sounder to activate when an expander
trouble condition occurs.
1. Ensure the advanced menu is enabled.
2. Navigate with the µ¶ keys to Control Panel>Outputs>Keypads>Sound On and press OK.
3. Scroll to Expander Trouble>Enabled and press OK.
4. The keypad beeps once to confirm the change and returns to Expander Trouble.
2.4 Assigning codes
System codes can be either four or six digits long. There are two types of programmable code; an installer code
and a duress code. A duress code disarms the system and activates a duress alarm. This is a silent alarm that
sends a special report to the central station. To program codes, select Installer Menu>Control Panel>Codes.
2.4.1 Setting up the installer code
An installer code has associated arming options and access rights. To set the authority and access rights, you
must enable the advanced menu. The following example assign partitions 1 and 2 to a new installer code that can
be used only to arm the system.
1. Ensure the advanced menu is enabled.
2. Navigate with the µ¶ keys to Control Panel>Codes>Installer Code and press OK twice.
3. Enter the new code and press OK.
4. Enter the new code and press OK.
5. The keypad beeps once to confirm the change and returns to Code.
6. Scroll to Authority>Arm Only>Yes and press OK.
7. The keypad beeps once to confirm the change and returns to Arm Only.
8. Navigate with the µ¶ keys to Partitions and press OK.
9. Press the corresponding numerical key to include partitions 1 and 4 and to exclude all other partitions and
press OK.
10. The keypad beeps once to confirm the change and returns to Partitions.
Duress Code
Code
Arm Only After Closing
Arm Only
Arm/Disarm
Master Code
Bypass Zones
Reports Open/Close
Installer Code
4/6 Digit Codes
Authority
2.3.1
2.3.2 2.3.2.1
2.3.2.2
2.3.2.2.1
2.3.2.2.2
2.3.2.2.3
2.3.2.2.4
2.3.2.2.5
2.3.2.2.6
Partitions
2.3.2.3
2.3.3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Security CS275 and is the answer not in the manual?

GE Security CS275 Specifications

General IconGeneral
BrandGE Security
ModelCS275
CategorySecurity System
LanguageEnglish

Related product manuals