CS875-575-375-275-175 Installers Manual with CS5500 keypad B.15.4
15.3.1 Configuring TCP/IP reporting
The CS7050 TCP/IP module can report to two receivers. You can configure the events to be reported, the
reporting format and the reporting connection parameters. The following example uses TCP/IP reporting to send
primary reports for tamper events occurring in partition 1 to receiver 1 (IP address 122.168.1.1).
1. Navigate with the µ¶ keys to CS7050 TCP/IP Module>TCP/IP Reporting>Receiver (1) and press OK.
2. Scroll to IP Address and press OK.
3. Enter 122.168.1.1 and press OK.
4. The keypad beeps once to confirm the change and returns to IP Address.
5. Scroll to Events>Tamper/Trouble>Tampers and Restores and press OK.
6. Press the relevant keys to include partition 1 in the tamper and restores event report.
7. The keypad beeps once to accept the change and returns to Tampers and Restores.
8. Navigate with the µ¶ keys to Options>Reporting>Report Format and select the format relevant for your
central station receiver.
9. Obtain the IP port and IP address, gateway and subnet mask for the CS7050 TCP/IP module:
- For Windows 9X / Windows ME, type ipconfig at the DOS prompt.
- For Windows 2000 / XP, type ipconfig at the COMMAND prompt.
10. Navigate with the µ¶ keys to Network and press OK.
11. Scroll in turn to Our IP Address, Gateway IP Address, Subnet Mask and Port Numbers and enter the
information obtained in step 9.
15.3.2 Configuring email reporting
Reporting to email addresses can include computers, cell phones, pagers and devices.
You can configure the
events to be reported, the reporting format and the reporting connection parameters. When using email reporting,
you must configure the server settings and the CS7050 email address and port. The following example uses
email reporting to send primary reports for alarms occurring on in partition 2 from ouremail@myemail.com to
email address 1 (user1@myemail.com).
1. Navigate with the µ¶ keys to CS7050 TCP/IP Module>E-mail Reporting>Our E-mail Address and press
OK.
2. Enter ouremail@myemail.com and press OK.
3. The keypad beeps once to confirm the change and returns to Our E-mail Address.
4. Scroll to E-mail Accounts>E-mail 1>E-mail Address and press OK.
5. Enter user1@myemail.com and press OK.
6. The keypad beeps once to confirm the change and returns to E-mail Address.
7. Scroll to Events>Arm/Disarm/Alarm>Alarms and press OK.
8. Press the relevant keys to include partition 2 in the alarms report and press OK.
9. The keypad beeps once to accept the change and returns to Alarms.