CS875-575-375-275-175 Installers Manual with CS5500 keypad C.1.5
Lost The system has not received
RF sensor transmissions for a
long period of time. Depending
on how the system is
programmed, this condition
activates a service report. In
addition, it may activate a
tamper alarm if armed.
Ensure that the wireless zone module is receiving power and has
not been tampered with. Repair any faults.
Low Battery An RF sensor battery is low. Replace the battery.
Short Loss The system has not received
RF sensor transmissions for a
short period of time. This
condition prevents arming.
Ensure that the wireless zone module is receiving power and has
not been tampered with. Repair any faults.
Trouble There is a problem with the
wiring.
Check the zone and zone sensors for damage and repair any
faults.
Table 1-5: Service messages
Message Definition Action