7.4.3.2 User Accounts
To configure local user accounts and local user account policy, click Security > User
Accounts.
Figure 81: Reason H49 Web User InterfaceLocal User Account Configuration
Note:
This page allows the user to create, edit and remove local user accounts. These user accounts are used only if no LDAP account
management has been defined or if the LDAP server is not accessible. If local authentication is used, then its associated
authorization will also be local.
Set the user account properties as described below:
Attribute Description
Password Complexity
Enables account password complexity. When checked,
user’s password shall fit the following restrictions:
Minimum length of password
At least 4 character types: Upper, Lower, Numeric
& Special.
Minimum Length
Sets the minimum number of characters required when
Password Complexity is checked. You can select a value
between 3 and 20
Password Expiration Period
Password expiration period defined in months between
0 and 24.
0 means that the passwords never expire.