GEDA
®
SUSPENDED WORKING PLATFORM AB 450 / 650 Operation
BL061 GB Edition 04/2016
67 / 96 Assembly and operating manual
6.3.3 Emergency shut-down
In situations that present a risk to operating personnel or the transport
platform, the platform can be shut down by pressing an EMERGENCY
STOP button.
There is an EMERGENCY STOP button on the central control box.
EMERGENCY STOP slam buttons are
equipped with a latching mechanism and
remain active until they are manually
unlocked again (turn red button to the right
and pull it out).
6.4 Interrupting work – end of work
¾ Move the working platform down.
¾ Unload the working platform.
¾ Press the EMERGENCY STOP button.
¾ Disconnect the mains plug.
6.5 Accessories
6.5.1 Cold package
The suspended working platform may only be used down to -20 °C. In
countries where work is carried out at lower temperatures, it is
recommended to install a cold package.