8.4 Wear and Function Checks
8.4.1 Check for overload
¾ Disconnection of the control with max. 125% of the rated load.
The red control light on the control must be lit in case of overload.
¾
Reduce the load in the complete machine until
the red control light (7) goes out.
Travel is possible again now.
8.4.2 Check EMERGENCY LIMIT limit switch
The winch must stop immediately if the
EMERGENCY LIMIT limit switch is operated.
No drive is possible any more (both directions
blocked).
Limit switch on C-clamp
Limit switch on the winch bracket