GEDA
®
SUSPENDED WORKING PLATFORM AB 450 / 650 Malfunctions – Diagnosis – Repair
BL061 GB Edition 04/2016
83 / 96 Assembly and operating manual
Rope stop has triggered in the event of a power failure
As a result of this, no emergency lowering is possible.
To carry out emergency lowering of the working platform, proceed as
follows:
¾ Open the cover (2) over the motor.
¾ Release the brake by pulling the lever (1).
¾ Turn the hand wheel (3) anti-clockwise until
the rope stop can be released (approx.
5 cm).
¾ Pull the lever (4) up to release the rope stop.
¾ Perform emergency lowering as described
above.
¾ Determine the cause of the trigger.
(Refer to Chapter 9.1)