48 ADV100 Functions description and parameters list
2 Three wire Three wire control
The default use of the FRC block is shown below.
The Start command is linked to the Start terminal and the Reverse command is linked to Ramp ref invert.
The function diagrams of the 3 modes are shown below.
When 0-Normal control is set the motor only starts rotating when the FRForward command is sent. If the FRRe-
verse command is present the motor rotates in the reverse direction,
The FRstartmon output repeats the status of the FRForward command, while the FRreversemon output re-
peats the status of theFRReverse command.
When set to 1-Twowire control, the motor only rotates if the FRForward command or FRReverse command is
present. The simultaneous presence of the FRForward and FRReverse commands causes the motor to stop.
The FRstartmon output is enabled if the FRForward and FRReverse commands are not present simultaneously.
The FRreversemon output repeats the status of the FRReverse command.