48 ADV100 • Functions description and parameters list
2 Three wire Three wire control
The default use of the FRC block is shown below.
The Start command is linked to the Start terminal and the Reverse command is linked to Ramp ref invert.
The function diagrams of the 3 modes are shown below.
When 0-Normal control is set the motor only starts rotating when the FRForward command is sent. If the FRRe-
verse command is present the motor rotates in the reverse direction,
The FRstartmon output repeats the status of the FRForward command, while the FRreversemon output re-
peats the status of theFRReverse command.
When set to 1-Twowire control, the motor only rotates if the FRForward command or FRReverse command is
present. The simultaneous presence of the FRForward and FRReverse commands causes the motor to stop.
The FRstartmon output is enabled if the FRForward and FRReverse commands are not present simultaneously.
The FRreversemon output repeats the status of the FRReverse command.