EasyManua.ls Logo

Gemalto Prox-SU - Leds States for the Boot-Loader

Default Icon
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Reference Manual Preliminary
Prox–DU & Prox–SU
www.gemalto.com Release for first samples Do not use for final design
DOC118569A Public Use Page 116/134
‘e’,0x00,
‘r’,0x00,
‘f’,0x00,
‘a’,0x00,
‘c’,0x00,
‘e’,0x00,
Table 54 – USB Boot-loader Interface String Descriptor
LEDs states for the boot-loader
4 LEDs states are possible for the boot-loader according to the following table:
Yellow
LED
Blue
LED
State
Off Off
The reader is not in operation (not powered, in suspend mode or
failure)
Blink 1 Blink 1 The boot-loader is ready
Blink 2 Blink 2 The download operation is in progress
Blink 3 Blink 3 The download operation failed
Blink 4 Blink 4 The firmware check operation failed
Table 55 : LEDs states for the Boot-loader LEDs
Blink 1: 250 ms on every 500 ms. (When the yellow LED is on, the blue LED is off and vice-
versa)
Blink 2: 100 ms on every 200 ms. (When the yellow LED is on, the blue LED is off and vice-
versa)
Blink 3: 50 ms on every 100 ms. (When the yellow LED is on, the blue LED is on).
Blink 4: the yellow LED is on and the blue LED is off for 400 ms every 500 ms.

Table of Contents