DOC118569A Public Use Page 74/134
7 bStatus 1 00h, 01h,
02h, 40h,
41h, 42h
Slot status register:
0Xh = no error
4Xh = command failed
X = 0 card present and active
X = 1 card present and inactive
X = 2 card not present
8 bError 1 00h-FFh Slot error register:
Error when bStatus = 4Xh
9 bClockStatus 1 00h Value =
00h – Clock running
RDR_to_PC_Parameters
This message is the response to the PC_to_RDR_GetParameters,
PC_to_RDR_ResetParameters and PC_to_RDR_SetParameters commands.
Offset Field Size Value Description
0 bMessageType 1 82h RDR_to_PC_Parameters
1 bwLength 4 Size of the
abProtocolDataStructure field
5 bSlot 1 00h Slot number : Same as Bulk-OUT
message
6 bSeq 1 00-FFh Sequence number : Same as Bulk-
OUT message
7 bStatus 1 00h, 01h,
02h, 40h,
41h, 42h
Slot status register:
0Xh = no error
4Xh = command failed
X = 0 card present and active
X = 1 card present and inactive
X = 2 card not present
8 bError 1 00h-FFh Slot error register:
Error when bStatus = 4Xh
9 bProtocolNum 1 00h, 01h Specifies what protocol data
structure follows.
00h = structure for protocol T=0
01h = structure for protocol T=1
10 abProtocolDataStructure Byte
array
00h, 01h Protocol data structure
Protocol data structure for protocol T=0 (bProtocolNum = 0) (dwLength = 00000005h):
Offset Field Size Value Description
10 bmFindexDindex 1 b7-4 – FI selecting a clock rate
conversion factor
b3-0 – DI selecting a baud rate
conversion factor
11 bmTCCKST0 1 00h, 02h For T=0,
b0 – 0b
b7-2 – 000000b
b1 = 0 direct convention used
b1 = 1 inverse convention
used
12 bGuardTimeT0 1 00h-FFh Extra Guard Time between two
characters. Add 0 to 254 etu to the
normal guard time 12 etu. FFh is
the same as 00h
13 bWaitingIntegerT0 1 00h-FFh WI for T=0 used to define WWT
14 bCLockStop 1 00h ICC clock stop support

Table of Contents

Other manuals for Gemalto Prox-SU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemalto Prox-SU and is the answer not in the manual?

Gemalto Prox-SU Specifications

General IconGeneral
BrandGemalto
ModelProx-SU
CategoryCard Reader
LanguageEnglish

Related product manuals