Reference Manual Preliminary
Prox–DU & Prox–SU
www.gemalto.com Release for first samples Do not use for final design
DOC118569A Public Use Page 55/134
Load Keys error codes
65h 81h Memory failure
67h 00h Wrong length
69h 83h Reader key not supported
69h 85h Secure transmission not supported
69h 88h Key number not valid
69h 89h Key length is not correct
General Authenticate error codes
67h 00h Wrong length
69h 82h Security status not satisfied
69h 83h Authentication cannot be done
69h 85h Secure transmission not supported
69h 86h Key type not known
69h 88h Key number not valid
6Ah 81h Function not supported
6Bh 00h Wrong parameter P1-P2
6Dh 00h Instruction code not supported
Read Binary error codes
62h 82h End of data reach before Le bytes (Le is greater than data length)
67h 00h Wrong length
68h 00h Class byte is not correct
69h 82h Security not satisfied
69h 85h Address out of range
6Ah 81h Function not supported
6Ch XX
Wrong length (wrong number Le; XX is the exact number) if Le is
less than the available data length
Update Binary error codes
67h 00h Wrong length
69h 82h Security not satisfied
69h 85h Address out of range
6Ah 81h Function not supported
Table 17 – Memory card error codes