4-12
Chapter 4 REGISTRATION MARK SETTINGS AND DETECTION
(10) Use the [ ] [ ] [ ] [ ] keys to move the pen carriage (the tip of the tool selected by the current setting) to the
area under the cross symbol indicated in the diagram below) and then press the
[ENTER] key. The sensor will read
the cross symbol.
Move the pen carriage (the tip of the tool selected
by the current setting) within this area.
Y
X
(11) After the sensor reads the cross symbol, a cross symbol for use in adjustment is plotted using the pen in tool holder
1 and then the menu below is displayed.
FORCE OFFSET
SPEED QUALITY
SENSOR OFFSET ADJUST
X= 0.0 mm Y= 0.0 mm
Inputthedifferenceinvaluesbetweentherstandsecondcrosses.Ifthereisnodifference,simplypressthe[ENTER]
key.
Press the [F2] or [F4] key to move the blinking cursor to X or Y, and then use the [ ] or [ ] key to change the
numeric value. When the displayed setting is satisfactory, press the
[ENTER] keytoconrmyourselection.
Setting range: -9.9 to +9.9 (mm)
Cross plotted after the first cross was read
Value for X-axis correction
Value for Y-axis correction
Y
X
(12) Press the [PAUSE] key to cancel PAUSE mode.
Adjusting the Registration Mark Sensor by Using One Plotted and One Cut Cross Symbol
The plotter plots a cross symbol, reads it, and then uses the cutter pen to cut a second cross symbol. The sensor’s
precision is adjusted by inputting the difference in the values of these two cross symbols.
Perform this adjustment after the registration mark detection level and registration mark detection speed settings
have been made.
(1) Load a medium for the sensor adjustment procedure.
(2) Press the
[PAUSE] key to select PAUSE mode.
(3) Press the
[NEXT] key repeatedly until the following menu is displayed.
FORCE OFFSET
SPEED QUALITY
MARK TOOL U/D
BUFFER CLR. VIEW
(4) Press the [F1] key (MARK) to display the registration mark functions selection menu.
FORCE OFFSET
SPEED QUALITY
MODE DIST ADJ
TYPE OTHER SETUPS
(5) Press the [F4] key (OTHER SETUPS) to display the menu shown below.
FORCE OFFSET
SPEED QUALITY
SIZE ADJ. SENS
ORG OFT SENS OPT

Table of Contents