GRAPHTEC FC2250 Series - Configuring Step Pass for Detailed Cutting

GRAPHTEC FC2250 Series
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-23
Chapter 5 FUNCTION SETTINGS AND OPERATIONS
5.21 Setting the Step Pass
Use this function when you intend to cut extremely detailed data. The cutting data sent from the computer
willbeprocessedinblockscorrespondingtothenumberofstepsspeciedbytheSTEPPASSfunction,
thereby ensuring consistent blade control and higher cutting quality.
(1) Press the [PAUSE] key to select PAUSE mode.
(2) Press the
[NEXT] key repeatedly until the following menu is displayed.
FORCE OFFSET
SPEED QUALITY
OPTION1 OPTION2
(3) Press the [F2] key (OPTION1) to display the menu shown below.
FORCE OFFSET
SPEED QUALITY
START FCE OFST ANG
OFST FCE STP PASS
(4) Press the [F4] key (STP PASS) to display the step pass setting screen.
FORCE OFFSET
SPEED QUALITY
STEP PASS
STEP PASS = 1
Use the [ ] or [ ] key to change the numeric value, and then press the [ENTER] keytoconrmyourselection.
Setting range: 0 to 20 [Default value: 1]
10 2 18 19 20
If the STEP PASS setting is set too high, the cut shapes may become deformed. The recommended STEP PASS
setting is "STEP PASS= 1".
(5) Press the
[PAUSE] key to cancel PAUSE mode.
This setting is retained in the plotter's internal memory even while the plotter is turned off.