4-13
Chapter 4 REGISTRATION MARK SETTINGS AND DETECTION
(6) Press the [F3] key (ADJ. SENS) to display the menu shown below.
FORCE OFFSET
SPEED QUALITY
X ADJUST SENS. Y
X+ Y+
(7) Press the [F2] key (X+) to adjust the X-axis sensor, and the [F4] key (Y+) to adjust the Y-axis sensor. The prompt
shown below is displayed.
FORCE OFFSET
SPEED QUALITY
CHANGE TOOL
PRESS ENTER KEY!
(8) Mount a plotting pen in tool holder 1.
(9) Press the
[CONDITION] key to display a condition settings screen, and then use the [F1] to [F4] keys to select a
COND No. where "PEN" has been selected as the cutter blade type.
(10) Use the
[ ] [ ] [ ] [ ] keys to move the pen carriage (the tip of the tool selected by the current setting) to the
position where you want to plot the cross symbol and then press the
[ENTER] key. The plotter plots a cross symbol,
and then the prompt shown below is displayed.
FORCE OFFSET
SPEED QUALITY
CHANGE TOOL
PRESS ENTER KEY!
(11) Replace the plotting pen with a cutter pen.
(12) Press the
[CONDITION] key to display a condition settings screen, and then use the [F1] to [F4] keys to select a
COND No. where a cutter blade has been selected as the cutter blade type. Press the [ENTER] key. The sensor
reads the plotted cross symbol, and then cuts a second cross symbol. After the second cross symbol has been cut,
the screen shown below is displayed.
FORCE OFFSET
SPEED QUALITY
SENSOR OFFSET ADJUST
X= 0.0 mm Y= 0.0 mm
Inputthedifferenceinvaluesbetweentherstandsecondcrosses.Ifthereisnodifference,simplypressthe[ENTER]
key.
Press the [F2] or [F4] key to move the blinking cursor to X or Y, and then use the [ ] or [ ] key to change the
numeric value. When the displayed setting is satisfactory, press the
[ENTER] keytoconrmyourselection.
Setting range: -9.9 to +9.9 (mm)
Cross that was cut after the first cross was read
Value for X-axis correction
Value for Y-axis correction
Y
X
Cross that was plotted first
(13) Press the [PAUSE] key to cancel PAUSE mode.