4-17
Chapter 4 REGISTRATION MARK SETTINGS AND DETECTION
4.9 Setting the Registration Mark Detection Speed
This function sets the speed of the pen carriage at the time when registration mark lines are detected.
Change the speed setting if registration marks cannot be detected due to the type of media used or the
thickness of the registration mark lines.
(1) Press the [PAUSE] key to select PAUSE mode.
(2) Press the
[NEXT] key repeatedly until the following menu is displayed.
FORCE OFFSET
SPEED QUALITY
MARK TOOL U/D
BUFFER CLR. VIEW
(3) Press the [F1] key (MARK) to display the registration mark functions selection menu.
FORCE OFFSET
SPEED QUALITY
MODE DIST ADJ
TYPE OTHER SETUPS
(4) Press the [F4] key (OTHER SETUPS) to display the menu shown below.
FORCE OFFSET
SPEED QUALITY
SIZE ADJ. SENS
ORG OFT SENS OPT
(5) Press the [F4] key (SENS OPT) to display the menu shown below.
FORCE OFFSET
SPEED QUALITY
LEVEL
SENS SPD SENS STEP
(6) Press the [F2] key (SENS SPD) to display the menu shown below.
FORCE OFFSET
SPEED QUALITY
SENSING SPEED
SPEED = 5 cm/s
Use the[ ] or [ ] key to change the numeric value, and then press the [ENTER] keytoconrmyourselection.
Setting range: 1 to 30 (cm/s) [Default value: 5]
Setting a slower speed (a smaller value) enables registration marks to be detected more easily.
(7) Press the
[PAUSE] key to cancel PAUSE mode.