5-10
Chapter 5 FUNCTION SETTINGS AND OPERATIONS
5.9 Assigning Tool Numbers
This function enables you to assign tool holder 1 and tool holder to COND Nos. 1 to 8.
If the application software is used to perform pen exchange operations, "PROGRAM" must be selected for the
CONDITION PRIORITY setting (please see Section 5.27, "Using the Special Functions").
(1) Press the [PAUSE] key to select PAUSE mode.
(2) Press the [NEXT] key repeatedly until the following menu is displayed.
FORCE OFFSET
SPEED QUALITY
I/F FUNCTION
TOOL COND AREA OPT
(3) Press the [F2] key (TOOL COND) to display the menu shown below.
FORCE OFFSET
SPEED QUALITY
THICK CUT LINE
TOOL No. ADJ.T POS
(4) Press the [F2] key (TOOL No.) to display the tool number assignment setting screen.
FORCE OFFSET
SPEED QUALITY
COND No. 12345678
TOOL No. 11112222
The upper row of the display represents the cutting condition COND Nos. Use the [ ] or [ ] key to move the
blinking cursor underneath the CONDITION No. for which you wish to change the current tool assignment, and then
use the [ ] or [ ] key to toggle the tool number between 1 and 2.
The factory default settings are those shown in the above screen.
Press the [ENTER] keytoconrmyourselections.
(5) Press the
[PAUSE] key to cancel PAUSE mode.
These settings are retained in the plotter's internal memory even while the plotter is turned off.