EasyManua.ls Logo

GRAPHTEC FC9000 Series - Page 177

GRAPHTEC FC9000 Series
402 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-27
9
Using "+" plotted with the cutter plunger (Tool 1) as a
reference, measure how much the "+" cut by the pen plunger
(Tool 2) deviates. (For example, in the case shown in the
ÀJXUHLWLVGHYLDWHGLQWKH;GLUHFWLRQ<GLUHFWLRQVRHQWHU
X = + * mm, Y = - * mm.)
X mm
Y mm
"+" plotted with
the cutter plunger
(Tool 1)
"+" plotted with the
pen plunger (Tool
2)
10
Press the [3] key (X=+0.0mm).
7RRO,QWHUYDO$GMXVWPHQW;VFUHHQLVGLVSOD\HG
Supplement
You can set the range between -3.0 mm and
+3.0 mm.
11
Press the POSITION ( ) keys and increase or decrease the
setting value.
12
&RQÀUPWKHVHWWLQJDQGSUHVV>(6&@NH\35(9,286
TOOL OFFSET ADJ. screen is displayed.
13
Press the [4] key (Y=+0.0mm).
7RRO,QWHUYDO$GMXVWPHQWVFUHHQLVGLVSOD\HG
Supplement
You can set the range between -3.0 mm and
+3.0 mm.
14
Press the POSITION ( ) keys and increase or decrease the
setting value.

Table of Contents