FCX2000-UM-251-9370 1-6
1 INTRODUCTION
1.5 Regarding the Blower (Vacuum Pump)
The blower is not supplied by the VC models, therefore prepare the blower from local distributer of blower.
Select the blower according to the guidelines listed in the table below.
Item FCX2000-60VC FCX2000-120VC FCX2000-180VC
Ratings
Airow (m
3
/min) 0.3 0.5 0.5
Static pressure (kPa) 5.4 6.4 6.4
Hose connection bore 50.8 mm (2 inches)
Usually the connecting adapter which is between the hose and the blower is not including to the blower.
Prepare the connecting adapter from local distributer of blower.
The following picture is showing the connection of the blower and the FCX2000.
Hose band
Hose band
Durable flexible hose
Blower mounting stand
Blower
Connect to the
power outlet
Hose adapter
Prepare the blower and the hose adapter locally.