FCX2000-UM-251-9730 4-17
4.
OPER ATIONS
4.8 Selecting Tool Condition
Set the “TOOL CONDITION (Cut Condition) No.”, “TOOL”, “OFFSET”, “FORCE”, “SPEED”, and “ACCEL
(ACCELERATION)”.
Selected condition
User number
Tool condition number that is currently being used
4.8.1 Selecting the tool condition number
Eight settings (1 to 8) as the tool condition can be stored. By switching this setting, it can be switched to 8
types of label material-specic settings that have been set previously.
Operation Method: Operation with the [COND/TEST] key
(1) Press the [COND/TEST] key from READY status.
CONDITION setting screen (1/4) is displayed.
(2) Press the [1] key.
CONDITION No. selection screen is displayed.
(3) Press the POSITION (▲▼) keys and select the setting.
(4) Conrm the setting and press the [ENTER] key.
Setting will be set, and it will return to CONDITION screen (1/4).
(5) Press the [COND/TEST] key.
It will return to default screen.