EasyManua.ls Logo

GRAPHTEC FCX2000 - Page 161

GRAPHTEC FCX2000
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FCX2000-UM-251-9370 9-15
9 ELECTRICAL ADJUSTMENTS
(5) The following menu will be displayed.
The adjustment values are possible to copy to the new main board if the status of SERIAL NUMBER and
the FACTORY_VALUE are showing the “OK”.
When the serial number is showing the “A-1”, the SUB-NVRAM was not exchanged from the previous
main board or the previous main board was not replaced at this procedure.
If FACTORY_VALUE status are showing the “NG”, all adjustment values have to input manually from the
factory adjustment value label except the registration sensor level adjustment.
The registration sensor level adjustment have to adjust manually.
Afteralladjustmentswerenished,theadjustmentvalueshavetoupdatetotheSUB-NVRAM.
Refer to the section 9.16 to update the SUB-NVRAM values correctly if the status are showing “NG”.
(6) Press the F1 key to copy the adjustment values to the main board.
(7) Theplotterwillbeinitializedautomaticallyafterthevaluesarecopedtothemainboard.
(8) Turn off the power.