10 TROUBLESHOOTING
Error cord No. LCD Display Cause Solution
E01022
There was a heavy load
on the up and down
function of the tool
carriage.
Remove the object disturbing
the operation, and then turn
on the power after turning off
the power.
The Y or X exible cable
has damage.
Conrm the Y or X exible
cable is not broken.
Replace the Y or X exible
cable when it is broken.
There is the dust on the
pen height encoder strip.
Removethe
dust from the
pen height encoder strip.
The pen height encoder
strip has damage.
Replace the pen block
assembly when the pen height
encoder strip has damage.
Theexiblecable
forthepenheightis
broken.
Replace the pen block
assembly when the exible
cable for the pen height has
damage.
The wire of MC coil is
broken.
Conrm the MC coil moves
smoothly.
There is possibility of broken
MC coil if it is not moved
smoothly.
Replace the Replace the pen
block assembly.

Table of Contents